hayward blue essence troubleshooting
Its a little over 3 years old and the cell checked out fine. Scoop out debris left in basket area, and try again. Troubleshooting Guides To view these documents, you will need to download the free Acrobat Reader, which gives you instant access to PDF files. Hi there. But the clicking, that sounds like a centrifugal switch, on the rear of the shaft, which could be a voltage issue? Is this the proper way to wire this salt water panel or does it also have to have a cable going into N0-2? Ohms reading should be between 0.5 and 1.0 ohms max. Remember also with DE powder, it is half-weight of other dry measure, so if instructions say 5 lbs of DE powder, thats not 10 8-oz cups of dry measure (kitchen measure), its actually double that, or 10 lbs, if you were using a 1-cup measure. For some time now I have been pushing along with my old cell (t-9 model). Or switch to Pentair, but I wouldnt say theyre better your case is unusual, the pump may have been dropped, suffered some hard knock from a tree branch, or perhaps it had a defective bearing to begin with. Hi Kevin, I think I would check the capacitor(s), maybe replace them if they test weak, or look cracked or damaged. Does the panel just need to dry or did I cause possible damage? Just wired and installed a brand new Century 1 hp pump motor on a Hayward Super pump filter, getting power to the terminals of the motor but motor does not start, shaft spins freely. Pump is less than 3 years old. the motor makes humming sound but nothing happened, then the motor became burning hot. JavaScript is disabled. anyway I digress. ), or the valves that are before the pump. And make sure the bolts are tight of course. Hi Don, when its not an air leak, pump surging will then be an obstruction in the pipe, or filter, heater, check valve/filter valve/diverter valve, a bit of plastic usually (once I found a golf ball, in the skimmer pipe), that is pulled into a 90 or up against a port that is too small for the obstruction to pass. Automatic reset is immediate when the switch opens. Step 2: Verify that you have enough straight pipe before where you have installed your flow switch. I have a Hayward sp 2603 vsp pump which is a year old has been working fine but 2 days ago I turned it on it ran about 1 minute, it cut off and on the display it says error code 11 and it will not run. It was only 3 years old. If a LED is flashing, wait 60 seconds after starting the filter pump. The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. Calling the pool builder for warranty info, too. Rob, the air leak is coming from the pump, or before the pump. Did you figure out your problem? otherwise all else seems to read ok. Id check the cell number just to confirm it is the TCELL15. Hi Leah, good question, and I understand. Mine just did the same. Lets see what we can do Air leaks or other obstructions BEFORE the pump (including a clogged impeller), will cause lower than normal filter pressure. There is not much that can be done to increase flow rates for a smaller pump, with exception to reducing plumbing restrictions with larger pipe size and less elbows, etc. "caption": "In The Swim Blog"
Another oddity is both failure are upon Spring re-opening,and the pumps ran flawlessly throughout each summer? Is it possible pump too small for AV60 filter? Do you have the correct cell size chosen in your diagnostics menu? Is there a reset button or do I just need to wait until the water evaporates and it should turn back on? Seal up the air leak in the front of the pump, then bleed off all the air in the filter tank, and the bubbling should cease. Check the motor diagram for the voltage wiring diagram. Tool pump out of storage and hooked up as normal. Big mistake! Automatic reset is immediate once the gas valve relay check results are acceptable. Might wait to see if Hayward can give you an answer and probably want to contact the vendor who sold you the pump, which Hayward may require anyway? Hi it could be small wood chips stuck in the pump impeller. Automatic restart is 2 minutes after the error is corrected. Just be sure to buy the correct seal for your make/model pump, for the Powerflo Matrix pump, thats here: https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c SPX1250XZ2C. Using a Filter Cleaner can help, there may be some goop and gunk in there, even after just months of operation. If power is tested at these points, I would check the motor terminals. Any suggestions? Could also be that your vacuum hose has a big split in it if this only happens during vacuuming. We would like to show you a description here but the site wont allow us. I just replaced a Hayward 2 hp SP2615X20 that started making a loud noise while still pumping, so I figured the bearings or something were gone, with a Hayward SP3015X20AZ 2 hp. We have a Hayward ultra pro lx series pump for our above ground pool. We would like to show you a description here but the site wont allow us. Then check power (volts) coming into motor to verify and if it still wont come on (and makes no attempt to) its likely dead. Hi, I have a Hayward pump and it was running my barracuda g3 just fine but it stopped hours later. Reset AquaRite Salt Chlorination Inspect Cell Light If the Inspect Cell Light is the only LED light flashing, then you can reset it by simply holding down the diagnostic button for 3 seconds, then release. I have an above ground 18,000gal poola Hayward SP1580X15 Power-Flo LX 1 1/2 HP pump purchased May 2017. Outlet works fine. Or spray with shaving cream (yes! I have a Hayward SP2610X15 Super Pump 1.5-HP Max-Rated Single-Speed Pool Pump, Cant find anything that jumps right out. Hi Davy, I have a brand new Hayward motor/pump as shown above on your site. Its not raw gas, but a sour smell. the tubes are sealed at the end by the two seal plates. I dont think I have any air or water leaks. While holding the shaft and trying to remove the impeller there was a part that broke off the shaft on the electrical end and I dont know what the part is and cant find it to order it. Especially a drip from the clamp band or the threaded fitting on the outlet port of the pump, or a dripping shaft seal, or leaking housing. 6. just replaced t15 on a rev 1.45 aqua rite and the default salt reading now is 4. 3 things are key, 1. If it still trips the breaker, it may have shorted out the motor windings, and is not repairable. But heaters? Hi Davy. I am very sure the water comes from underneath, not from plumbing fitting threads. how to watch past broadcasts on twitch. Hello. Hi Tony, there could be a short in the motor, or loose wires connecting to the capacitor, or if the capacitor you are replacing with is not the correct capacitor, or if the centrifugal or stationary switches are not releasing the capacitor, due to loose or misaligned switches, or loose wires, or wires shorting out by touching other wires or the motor casing, or crimped wires give a good look around the back of the motor, and try another capacitor, maybe call Hayward and ask for the correct capacitor MFD number for your horsepower of Northstar. We are trying to figure a way to start pumping the water put to clean the pool and get it going but we cant work the pump. Hi Dave, check the owners manual to be sure that the cord size used is proper for the motor, and the plug, is a 3-prong grounded plug? The trick is the little plug on the electrical panel MUST be moved to either 230 (up one) or to 115 (down). Great site. there is an air leak, on the pump lid, or around the pipe that comes into the pump, or the pump drain plug. Hi, if the switch wont flip to on, the timer tripper could be right at the point where it is about to trip, making it hard to turn to on. Now if it really is your pump, and not the heater making this noise, that I cant explain, must be the heater? Im losing my mind. Hi Carolyn, When a pump displays those symptoms, its usually an air leak or a collapsed suction hose, or a very dirty filter. Im very new to pools & pool maintenance in general. Or, a loose pipe coming into the pump can allow air intake. The pump is only one year old. Or do I have a friction issue in the impeller? It could be dead. I opened the back and everything looks fine, Hi Matthew, the pump capacitor is the first suspect, it may be weak and needs replacement. second most common is the pump lid or drain plug, lube the lid oring and teflon tape on the drain plug. I replaced the o-ring and it still leaks out the same spot. It is so poorly designed and the helper handle is basically useless because it bumps into the outlet flow tube and the jandy. Hi Since the pool is still being finished, the lines going to and from the pool are not installed yet so wanted to put water in there to test. I have a 2 HP Hayward two speed pump that is on its second season. Click Here to View Replacement Aquarite Parts The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing the , . I would also suspect the outlet or breaker, but you have tried a different one with the same result. If you see any damage, replace your flow switch. I wonder if I should spend the $200 for replacement control board, or if there is a better fix. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. LibriVox About. Most Common areas include the pump lid (must be very tight, with lubed lid o-ring), and the threaded pipe that comes into the FRONT of the pump (must be very tight and sealed if loose, use Pool Putty to fix, or replace the fitting) the effluent or exit pipe fitting leaking will not draw air, that is on the pressure side not the suction side. Tighten the fitting hand tight, plus 1/2 turn or so, until really snug, but not super-tight. Pump lids are all very tight, they need to be. Also make sure that the impeller wear ring is correctly facing, and that the seal plate and mounting screw are aligned properly, and that the diffuser and diffuser o-ring are seating properly. LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the ' '' ''' - -- --- ---- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. ' Old bronze pool pumps, like Sta-Rite and Anthony, that use Key Shaft motors with stub shafts need to be shimmed properly. If I shut the pump off for a little while and put it back on it repeats the same thing over and over, strong at first for about 5 minutes then weak. I believe there a water volume calculator, that can help us size the motor, the originally company who installed is not in business. You need to be really sure about the actual salinity reading. 5. low water level or skimmer weir blocking water flow ), hard to tell until the pump can be tested. Have no power at all going to my control panel. I do not have a owners manual and need help on draining the water from the feature and pump. I presume Ill be looking at buying a new pump next year. Some very old pumps have impellers that need shimming from time to time, or resetting the distance from the volute, but thats with keyed shaft motors, on older bronze pumps (not plastic). Hi Minglin, open up the pump lid, and remove the basket and check if anything is obstructing the impeller, like grass, gravel, seeds, etc. Its linked to an AutoChlor switcher and comes on twice a day but failed to switch on a couple of days ago. Replaced the flow sensor as it seemed to run when lower RPMs on the pump and it now seems to cut it off when the RPMs on the pump drop like it should, and it will cut off when temperature reaches set heat of 93 for the spa. If so, it will always read 100%. There should be no continuity. So, I dont think you can use this motor, (sorry), unless you are able to add another 110V wire, and run both connected wires from a Double pole breaker. If it still wont catch full prime, open up the pump so you can ream out the impeller vanes with wire or a skinny screwdriver. "name": "Davy Merino",
Our variable speed Hayward pump, when not running on highest speed, keeps resulting in FLO errors. Turned everything off, let the motor cool off and tried again. Everything just went downhill. If the voltage between the orange and black is not 12VAC, you need to replace the rectifier or the board. For the clamp band, yes the washer with the slightly smaller hole I.D. Pool360 - Blue-essence-20 20k Gal Salt Chlorination System - Poolcorp Hi Paul, could it be vibration noise? Could this be an issue with my pump? The breaker is still left on the on position any idea what it might be? Inspect and tighten the suction and discharge connections using Teflon tape. 240v Input voltage is present. IF that all looks good, consider replacing the capacitor. This usually means the motor needs to be replaced. It had been running ok this summer. Any insight would be helpful. The process, for changing a hayward pump seal is: 1. Thanks, Then it wouldnt turn back on. HI Bernard, sounds like it could have cavitation, or a pipe diameter that is too small but pipe is the same. You will get much more visibility by. Make sure you. I next realized the shaft (impellers) was frozen, and was able to free it up so it now spins smoothly. I am getting air bubbles coming from my return jets in my pool. I am getting 24VAC from top Rectifier to PCB Input, says it should be 12VAC. HI Alberto, if a motor is overheating, it normally takes about 15-20 minutes, and then the thermal overload switch, located in the rear of the motor, will trip, shutting off the pump for about 15-20 minutes, until it is cool enough to start again, on its own. All Products, View New Assy is $500. Electrician was here at least 4 times and did not find anything. Sometimes its the filter that is drawing in air, thru the air bleeder or clamp band or bulkhead, which causes the filter to drain out through the pump, and back to the pool. Our troubleshooting guide will help you get it up and running in no time. Size: PCB Main Circuit Board PCB Display Board PCB Main Circuit Board PCB Main Circuit Board PCB Display Board Or it could be an obstruction in the impeller, or anywhere before the impeller (clogged pipe, small pipe, partially closed suction valves, air leak) all of which will produce lower than normal filter pressure. I just have a problem with the motor pump, I turn ON Saturday morning and left all day working, On Sunday morning I try to turn on the pump but it only make a noise but water dont flow then it stop working, then on Monday do the same thing it only make noise for 3 minutes then it stop working. voltage reachs the stationary switch. If power is reaching the box, getting past the transformer, and the fuse is good, it sounds like the main PCB is the issue. 220v. The hotel has an excellent location, close to a wonderful coral reef, lagoon with natural pool and sandy beach, outdoor swimming pool available all year round, private beach area, kitesurfing center and bar. If there is an external 2-speed timeclock, check the wiring, esp. What am I doing wrong??? They disappear when the pump is at a high speed. I had to have a pool person come out & they got me good. power to my pool pump & timer quit working at the same time. We had a pool built in FL in Aug 2018 with variable speed Hayward TriStar pump. The unit works fine for approximately 4- 6 hours, then the Check Salt and Inspect Cell flashes (salt level on the unit reads 2600 ppm). Hi John, that is going to be either a cavitation noise, where the pump is starved for water, or if this noise is new, it would likely be the front and/or rear motor shaft bearings wearing out. The symptoms you describe could be shorted windings, or it could also be just a bad capacitor, or it could be a motor that is locked up, from small amounts of rust inside which is often the case for motors that have sat all winter long. Pressing on/off buttom followed only by click sound of switch. Jul 8, 2018 #1 I have a blue essense 20,000 salt system and can find very little online. Put your power leads on both sides of the transformer, should be 115V IN, and 28V OUT, (or close to those numbers). Hi Chris, is the vacuum hose fully primed with water before you attach it to the skimmer, you say primed and ready to go, so I assume so. The motor on my Hayward super pump 2 went out so I ordered a Hayward replacement. Hi Davy, Im trying to remove the impeller from a Hayward 1 HP superpump. If it is reversible is lists voltage on the label as 115V/230V, but if 230V only, it just says 230V. Bearings produce a loud squealy sound. Hello my Hayward pump before it starts it buzzes for a few seconds and stops for a few seconds then repeats and after a couple of trays it starts running normal. Put your foot on the motor and apply a little weight, to see if the noise stops. In most cases, no worries that it will blow-out to leave a leaking pump running. If they wont or cant fix it, call a electric motor repair shop to visit, or pull the pump and take it to them for service, or attempt the (easy) repair yourself. If error still occurs, replace drive. So, check that the air vents on the motor are not clogged, and that the fan in the rear is not clogged, or doesnt have something wrapped around the fan, and also around the pump, check that air flow is not blocked by mulch, or by pump being installed in a small box, or anything that prevents free flow of cool, outside air. They dont usually begin to flow like a gusher, but a steady trickle. Hi Kenny, not to my knowledge, you should see some display even without gas hookup. Also, because of this leak, would It cause my pressure to decrease? I just replaced my pump/motor at the start of this swimming season. Hi Pat, good question you can continue to use the IG pump, no problem. I will be purchasing a replacement pump and have it installed, but I wonder if Id need to just have the breakers tightened in the panel box? Bump shaft or diaphragm gasket? hayward blue essence troubleshooting - Prismatalk.de (The factory default is 2800 ppm). The cell is new. it continues to cycle this way. Again, flow rate is good but it doesnt make the change in pressure like it should when switching to sweeper. If communication between the ignition board and the display board is not established within 3 s of power-up an error will be displayed. If all is well then 99% sure it would be the capacitor, weak and needs replacement. I completely back washed and clean the system two times making sure the filter was put together properly and there were no holes in either the manifold or the filter grids. Hi Clara click doesnt sound like a motor runnning, perhaps you are hearing a relay click, but if the motor itself is not turning over there could be a multitude of reasons why, but in most of these cases, the problem lies where the power dies. That could explain the pumping problems. Mine is doing same thing. Today, I came home to find my pump off after leaving it on this morning. Any insight? },
Low speed should be enough flow to activate the flow switch. It looks like its coming from in between the motor and pump.Am I correct in thinking I need a new seal plate kit? Usually get 3-4x that long. A leaking shaft seal should not cause your filter pressure to decrease. Just hoping for some feed back and the name plate is missing from the Tristar Motor, to actually know the exact motor we have? Is this rare? By morning all the dead algae filters back into the pool and it take about 4 days to clear. Are you getting 230V (207v 253V) at the pump? regardless, i am replacing the electrical cord. If it is a union valve, cream also on the union nut. Returns are getting good supply, the gauge on filter is bouncing up and down. The correct replacement would be the AquaRite Main PCB (OEM) GLX-PCB-RITE. Backwash works but not filter.. we took it apart and replaced the housing gasket, diffuser gasket and seal shaft. "datePublished": "3/27/2015",
You may be removing the wrong bolts, if you are trying to loosen the 4 bolts that attach the motor to the seal plate. Any thoughts? Though it is a different control, they use the same cell; so if you are getting a temperature reading of 215, you need to replace the cell. My 2 year old 1.5 HP above ground Hayward pool pump worked fine last year. Good luck ~, Hi, I just replaced my 3/4 Hayward pump with a 1hp. This is Poolside Chat where every week we answer your questions on how to fix and maintain your swimming pool. They do not seem to have enough stooch even though they are rated at 1HP like my original motor. It is only in its 3rd season. For the pool winterization, the usual practice is to remove the filter and drain plugs, and then use rubber expansion plugs, or threaded plastic plugs, to close up the pool skimmer line and the pool wall return lines (where water returns to the pool), after the pipes are drained of water. Thank you for the quick response. Could also be loose connections on the wires, or insect infestation on the contacts. HI Mike, the seal and the motor may be separate issues or they may be related. It is good to let hayward know, because if they had a run of bad bearings, they will know about it, and want to know about it, and are more likely to help, if out of warranty. There may be some stray voltage running around the system, on the bonding wire. Have a Hayward SuperPump. Also could be a loose stationary switch (motor rear, 6 oclock) or a loose centrifugal switch (motor rear, dead center). This new one when turned on seems to start, and pump, but the breaker shuts off in probably less than a second. Also look for any burn marks on the wire terminal board, or any crimped wires running round the rear of the motor. And you cant rule out a problem with the circuit board either. The blower will continue to run. After we run the pump for a few minutes and then take the pump apart there is water in the impeller- but the water is where the seat housing is. The leak and the surging you are experiencing, could be a result of the high filter pressure. Can I replace a specific part or do I have to buy a new one? The regular tristar is only $100 cheaper now, so Id go for the Tristar VS. Guess it is time for a new drive. If the pump makes no noise at all, turn on power, and with a multi meter, check the power at the pump, switch/timer and breaker, the problem lies where the power dies. If the salt level is within range, go to Step 3. If you're researching Blue Essence, we're more than happy to help you figure out the best solution for replacing, upgrading, or repairing your system. I currently have Hayward RS750CA and it starts leaking underneath. Hi We just bought a new Hayward Powerflo Matrix pump and filter. I first thought it might be the motor capacitor, new cap, problem still the same.